User Guide

Clock Division NOTE: Available only if Output Type = “Clock (Always)” or
“Clock (Running)”
1-192 Selects a clock divisi on to apply to the incoming MIDI
clock.
If you assign the output to “Clock” (either “Always” or
“Running”), then you have the option of setting an arbitrary
number of clock divisions (from 1 to 192), rather than the
preset options offered by the module’s dedicated CLK
output.
Synth NOTE: Not available if Output Type = “Clock (Always),”
“Clock (Running),” “Reset” or “Run”
(1 - 10) Selects which Synth (1 - 10) is the source of that jack’s
output voltage. The Type of synth (as selected in the
Synths Column ) is also indicated. The output voltage
present at this jack is derived from whichever incoming
MIDI channel is assigned to that Synth (also selected in
the Synths Column).
CC Number NOTE: Available only if Output Type = “CC Number” or
“CC Number (High Res)”
(0 - 95) Selects which MIDI CC# is the source of the control
voltage sent out the jack. For example, if you select
5Portamento Time , then the jack will transmit a control
voltage based on CC #5 data on the MIDI Channel used
by the selected Synth.
NOTE: Not every value between 0 and 95 is available.
Those that aren’t are greyed out. Note also, that if the
Output Type = CC Number (High Res) , then fewer CC
sources are available than if Output Type = CC Number .
MIDI 1U System Manual 38