User Guide

Clock Division Selects a clock division to apply to the incoming MIDI clock.
The divided clock is sent out the CLK output.
/1 clock out = 24 ppq
/3 clock out = 1/32 notes
/6 clock out = 1/16 notes
/12 clock out = 1/8 notes
/24 clock out = 1/4 notes
/48 clock out = 1/2 notes
/96 clock out = whole notes
Clock Mode Always The received MIDI clock will be output regardless of the
Transport state (Start/Stop).
Running The MIDI clock will only be output when the Transport is
“running.”
RST Output Reset The RST jack transmits a trigger signal whenever a MIDI
RESET or START message is received. This is the factory
default.
Run The RST j ack transmits a run gate that goes high (5V) on a
MIDI START/CONTINUE message, and goes low (0V) when
a STOP message is received. This is useful for
starting/stopping any eurorack sequences in sync with an
external MIDI sequencer.
Single Mono MOD Output Settings
Use these settings to configure the source and type of signal sent from the MOD jack when MIDI 1U
is set to Single Mode.
IMPORTANT: These setting apply only when MIDI 1U is set to Single Mode , since the MOD jack is
used for synth 2’s Pitch output in Dual Mode ).
Output Type Selects the type of voltage sent out the MOD jack. By default,
this is a CC Number (the value of which is selected from the
CC Number menu), however other assignments are possible.
Specifically:
Clock (Always) The jack outputs a clock signal (timed at the rate set by the
Clock Division parameter, which appears when
“Clock (Always)” is selected). The received MIDI clock will be
output regardless of the Transport state (Start/Stop).
NOTE: If you assign the output to “Clock” (either “Always” or
“Running”), then you have the option of setting an arbitrary
number of clock divisions (from 1 to 192), rather than the
preset options offered by the module’s dedicated CLK output.
MIDI 1U System Manual 28