Section # 8 Industry Canada RSS-131 Requirements
IVWA819 Specifications per paragraph 5.3
1. The nominal passband gain is 65 dB.
2. The nominal bandwidth is, CDMA 1.2 MHz, TDMA 40 KHz, GSM 300 KHz
3. The rated mean output power:
0.664 W (28.22 dBm) 1850.025 – 1909.975 MHz
0.566 W (27.53 dBm) 1930.025 – 1989.975 MHz
4. The input and output impedance is 50 ohms
5. Notice: The Manufacturer’s rated output power of this equipment is for single carrier
operation. For situations when multiple carrier signals are present, there is no change in the
rating of the unit. Regardless of the input to the unit, the device will not exceed the rated
level of output. The output power per band is the same regardless of whether it is single or
multi-carrier operation.
Section # 9 Limited 1 Year Warranty
Cyfre™ warrants that this product is free from any defects in material or workmanship for a period of one year.
If a defect in material or workmanship is found, Cyfre™ agrees to repair or replace the product at its own
discretion, free of charge, to the original purchaser excluding all shipping charges. To return product, all parts,
packaging, and accessories along with original receipt from where you purchased your product must be included
with your return. Failure to return all product, parts, packaging, and accessories will result in product The
warranty is void if the product has been modified, abused, tampered with, or subjected to abnormal conditions.
Any use of non Cyfre™ antennas or cables will void this warranty.