Table of Contents Introduction .................................................................................................... 1 Pin Description ............................................................................................... 2 Pin Description ............................................................................................... 3 Absolute Maximum Rating ............................................................................. 4 Electrical Specifications ....................
APPENDIX A Recommended Cable Configurations: DC Supply to IMS Driver Cable length, wire gauge and power conditioning devices play a major role in the performance of your IMS Driver and Motor. NOTE: The length of the DC power supply cable to the IMS Driver should not exceed 50 feet. Example A demonstrates the recommended cable configuration for DC power supply cabling under 50 feet long.
E x a m p l e B – C a b l i n g 5 0 F e e t o r G r e a t e r, A C P o w e r t o F u l l Wa v e B r i d g e - + To Cable A NOTE: Connect the cable illustrated in Example A to the output of the Full Wave Bridge Full Wave Bridge Braided Shield Cable Length 50 Feet or greater Shielded/Twisted Pair (Wire Size from IMS Driver Supply Cable AWG Table) π Type RFI Filter ≥ Required Current Shield to Earth Ground on Supply End Only Transformer : 0 to 28 VAC RMS for 48 VDC Systems 20 to 48 VAC RMS for 75 VDC
E x a m p l e C – C a b l i n g 5 0 F e e t o r G r e a t e r, AC Power to Power Supply + DC Volts Out To Cable A NOTE: Connect the cable illustrated in Example A to the output of the Power Supply - Power Supply Braided Shield Cable Length 50 Feet or greater Shielded/Twisted Pair (Wire Size from IMS Driver Supply Cable AWG Table) π Type RFI Filter ≥ Required Current Shield to Earth Ground on Supply End Only 120 or 240 VAC Dependent on Power Supply 22
NOTE: These recommendations will provide optimal protection against EMI and RFI. The actual cable type, wire gauge, shield type and filtering devices used are dependent on the customer’s application and system.
Recommended Cable Configurations: IMS Driver to Motor Cable length, wire gauge and power conditioning devices play a major role in the performance of your IMS Driver and Motor. NOTE: The length of the DC power supply cable between the IMS Driver and the Motor should not exceed 50 feet. Example A demonstrates the recommended cable configuration for the IMS Driver to Motor cabling under 50 Feet long.
E x a m p l e B - C a b l i n g 5 0 F e e t o r G r e a t e r, IMS Driver to Motor Phase A Phase A Phase B Phase B Ferrite Beads Braided Shield Cable Length 50 Feet or greater Two Shielded/Twisted Pairs (Wire Size from IMS Driver to Motor Cable AWG Table) Phase A Common Mode Line Filters (2x) Phase A Shield to Earth Ground on Supply End Only Phase B Phase B *L ≈ 0.5 MH * 0.5 MH is a typical starting point for the Common Mode Line Filters.
IMS Driver to Motor Cable AWG Table 1 Ampere (Peak) Length (Feet) 10 Minimum AWG 20 5 Amperes (Peak) 25 50* 75* 100* 20 18 18 16 10 Minimum AWG 20 16 14 14 10 Minimum AWG 18 14 16 14 12 12 10 25 50* 75* 100* 14 14 12 12 7 Amperes (Peak) 25 50* 75* 100* 16 Length (Feet) Minimum AWG 14 3 Amperes (Peak) Length (Feet) 25 50* 75* 100* 6 Amperes (Peak) 25 50* 75* 100* 18 10 Minimum AWG 16 2 Amperes (Peak) Length (Feet) Length (Feet) 12 12 Length (Feet) 10 Minimum AWG 12 2
WARRANTY TWENTY-FOUR (24) MONTH LIMITED WARRANTY Intelligent Motion Systems, Inc. (“IMS”), warrants only to the purchaser of the Product from IMS (the “Customer”) that the product purchased from IMS (the “Product”) will be free from defects in materials and workmanship under the normal use and service for which the Product was designed for a period of 24 months from the date of purchase of the Product by the Customer.