Quick Start Guide
9
Setting Priming Time Press Select to access Max Priming Time.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing Up arrow and Down arrow.
When value is set, press Enter to con rm value and save changes.
Note:
The “System Priming Time” menu should only be used when excessive amounts of air need
to be evacuated from the system. IntelliFlo VF can prime in seconds, but additional time may be
needed to ll other devices – e.g., lters or solar heating systems.
Filter Menu Press Down arrow to scroll to Filter menu.
IntelliFlo VF is constantly monitoring lter pressure, and when it detects that the system needs
cleaning, an “Alert – Service System Soon” message will appear on the control panel display.
This parameter can be set from 69 to 3448 mbar, and establishes when the “Service System Soon”
alert will activate. Average setting should be between 690 and 1380 mbar for most pools and lters.
Note: mbar changes can come from anywhere in the system, e.g., clogged skimmers or pump strainer
baskets. Note: Initial start-up and installation of the IntelliFlo pump must always be performed with a
clean lter. If the lter has been in use, run the lter backwash cycle before start-up.
Press Select to access Clean Filter Pressure setting.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing Up arrow and Down arrow.
When value is set, press
Enter to con rm value and save changes.
Clean Filter Pressure
Filter 12:15
1 bar
1 bar
Clean Filter Pressure
®