Quick Start Guide

8
Priming Menu The Priming settings determine how long IntelliFlo VF will try to prime before it reports an error.
This is a critical setting for proper operation. The lower the time setting, the quicker a priming
error is reported if the system is dif cult to prime.
The Priming range can be set from 1 minute to 15 minutes.
Note: An IntelliFlo VF
mechanical seal will withstand approximately 15 minutes of attempted priming before before
damage occurs. If the pool is plumbed correctly,
IntelliFlo VF should prime in less than 30
seconds without removing the strainer. If the strainer has been removed for cleaning and a
substantial amount of air is in the system, IntelliFlo should prime in 60 to 90 seconds.
Important: IntelliFlo VF will prime every time it starts. If the priming  ow is set too high, equipment
damage could occur. If set too low, IntelliFlo will not prime. Establishing the correct priming  ow may
require some trial and error, but always keep the  ow as low as possible for cost savings and safety.
Setting Priming Flow Press Down arrow to scroll to Priming menu. Press Select to enter the Priming
menu.
Press Select to access “Max Priming Flow” value.
The available range is from 7 - 36 m
3
.
Press
Left arrow and Right arrow to select digit to modify.
Change values by pressing Up arrow and Down arrow.
When value is set, press
Enter to con rm value and program.
Priming time determines how long you want IntelliFlo to attempt to prime before reporting an
error. Time can be set from 1 to 15 minutes.
Pool Volume – Water Temperature – Priming
Priming 12:15
17 m
17 m3/h
Max Priming Flow
®
MENU 12:15
Priming
Priming
®