Quick Start Guide

13
Features – Flow Duration/Rate/Start–Stop Time
Features 3 – 9 Features 3 through 9 enable you to program speci c  ows for timed operation.
These features are fully controlled by IntelliFlo’s internal clock. You will need to program a  ow rate
and start/stop time for each feature.
Note: Feature 3 through 9 program times cannot overlap.
When a feature is running, IntelliFlo will monitor m
3
/h and subtract time from the  lter cycle.
All sensors are active during any Feature 3 – 9 cycle.
Enabling Features 3 – 9 Features must be enabled before they will operate.
To enable, press Select + Down arrow and Enter to save the setting.
Setting Flow Rate Flow Rate for Features 3 – 9
Press Down arrow to access Set Flow.
Press Select to access the Flow setting.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing Up arrow and Down arrow.
When value is set, press
Enter to con rm value and save changes.
Setting Start/Stop Times for Features 3 – 9
Press Down arrow to select Start Time or Stop Time Setting.
Press Select to access the setting.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing
Up arrow and Down arrow.
When value is set, press Enter to con rm value and save changes.