Quick Start Guide
10
Setting Priming Time – Filter: Turnovers/Cycles
Turnovers Per Day Press Down arrow to scroll to Turnovers.
This setting establishes number of times the entire volume of water will turn over per day.
One turn per day is recommended for energy conservation and for most common pool
requirements. This setting can also be modi ed to easily increase system ow if required for
more effective skimming. You can set up to eight turns per day.
Press Select to access Turnovers Per Day.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing
Up arrow and Down arrow.
When value is set, press
Enter to con rm value and save changes.
Cycles Per Day Press Down arrow to scroll to Cycles.
IntelliFlo VF uses the Cycles Per Day setting to calculate how much time it has to complete turn-
overs/ ltration. You can program up to four start/stop cycles per day. For instance, the pump can
lter from 9:00 to 12:00 and then from 14:00 to 21:00.
Press Select to access Cycle value.
Press Left arrow and Right arrow to select digit to modify.
Change values by pressing Up arrow and Down arrow.
When value is set, press
Enter to con rm value and save changes.
Filter 12:15
1
Cycles Per Day
®
Filter 12:15
1
Turnovers Per Day
®