Owner's Manual

Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner’s Manual • 9/20 22
Burner Ignition and Operation
Frequency: Annually
By: Quali ed Service Technician
Tools needed: Protective gloves, vacuum cleaner, whisk
broom, ashlight, voltmeter, indexed drill bit set, and a
manometer.
Verify burner is properly secured and aligned with pilot
or igniter.
• Clean o burner tube, inspect for plugged ports, corrosion
or deterioration. Replace burner if necessary.
Inspect for lifting or other ame problems.
Verify air shutter setting is correct. See Installation
Manual for required air shutter setting. Verify air shutter
is clear of dust and debris.
• Inspect ori ce for soot, dirt and corrosion. Verify ori ce
size is correct. See Service Parts List for proper ori ce
sizing.
Verify manifold and inlet pressures. Adjust regulator as
required.
Check all accessible gas-carrying tubes, connections,
pipes and other components for leaks.
• Inspect pilot ame pattern and strength. See Figure 45for
proper pilot ame pattern. Clean or replace ori ce spud
as necessary.
Inspect
IntelliFire Plus flame sensing rod for soot,
corrosion and deterioration. Polish with ne steel wool
or replace as required.
Verify IntelliFire Plus micro-amp output. Replace as
necessary.
Verify that there is not a short in ame sense circuit
by checking continuity between pilot hood and ame
sensing rod. Replace pilot as necessary.
Check for smooth lighting and ignition carryover to all
ports. Verify that there is no ignition delay.
Inspect and
ensure the lighting of the main burner occurs within four
seconds of the main gas valve opening.
Figure 4.5 IPI Pilot Flame Pattern