Owner's Manual

Heat & Glo • PRIMO48, PRIMO48ST, PRIMO60, PRIMO60ST, PRIMO72, PRIMO72ST Owner’s Manual • 9/20 16
HEAT-ZONE-PRIMO
The HEAT-ZONE-PRIMO is operated using a tempera-
ture switch. When the appliance is turned on, the HEAT-
ZONE-PRIMO will automatically turn on when the appli-
ance stabilizes at its operating temperature. This process
will take approximately 10-20 minutes.
After a quali ed service technician has installed the ap-
pliance, including the Heat-Zones
®
, follow the instruction
supplied with the appliance manual and accessory instruc-
tion for operation. Contact your dealer if you have ques-
tions.
Wall Switch
PowerFlow
TM
Heat Management System Toggle
LED COLOR
SWITCHES
Figure 3.7 PowerFlow
TM
Heat Management and LED Switch
PRIMO Passive Heat Kit
The Primo Passive Heat Kit (PHFR-PRIMO-48/PHFR-
PRIMO-60/PHSI-PRIMO) is operational when the appli-
ance is turned on. The heat is vented into the room.
After a quali ed service technician has installed the ap-
pliance, including the PowerFlow™ Heat Management
system, follow the instructions supplied with the appliance
manual
and accessory instruction for operation. Contact
your dealer if you have questions.
For additional information, see the instructions included
with the
appropriate PowerFlow™ Heat Management
System.
PowerFlow™ Heat Management Systems
Power Vent System
PVI-SLP-B, PVV-SLP or PVLP-SLP
WARNING! Risk of Fire! PRIMO models must be power
vented using PVI-SLP-B, PVV-SLP or PVLP-SLP. Failure
to vent properly could cause overheating and re.
A quali ed service technician will install desired power vent
system at the time of appliance installation.
The PRIMO comes standard with a 2 minute pre-purge
function designed to remove cold air and excess gas from
the gas lines.
The PRIMO comes standard with a 20 minute post-purge
function designed to eliminate condensation in the venting
system components.
For additional information, see the instructions included
with the power vent product.
The PRIMO requires a PowerFlow™ Heat Management
System. System options are:
HEAT-ZONE-PRIMO: The heat is diverted into an
adjacent room.
HEAT-OUT-PRIMO: The heat is diverted outside the
home/building.
PRIMO Passive Heat: The heat is vented into the room
in which the appliance is installed through discharge
opening(s).
At least one of these options must be installed and in
operation whenever the appliance is turned on. Because
the Passive Heat option is naturally drafted, it is the only
PowerFlow
TM
Heat management system that operates
automatically when the appliance is turned on.
HEAT-OUT-PRIMO
The HEAT-OUT-PRIMO is operated using a temperature
switch. When the appliance is turned on, the HEAT-OUT-
PRIMO will not turn on until the temperature switch has
reached a predetermined temperature. This process will
take approximately 10-20 minutes.
WARNING! Risk of Fire! A PowerFlow™ Heat
Management system must be installed and operating
when the appliance is turned on. Overheating of
appliance and combustible materials will occur.