1. The Electronic Control Module (IFT-ECM 2.0) has
a three-position ON/OFF/REMOTE selector switch
that must be set for proper operation. See Figure 12.
When changing switch positions,it is important to
pause in each position for 1-2 seconds.
OFF Position:
The appliance will not respond to any commands
from a wired wall switch, IFT-RC150 or IFT-RC400
remote controls. The unit should be in the OFF
position during installation, service, backup battery
installation, fuel conversion and to reset the IFT-
ECM 2.0 in the event the system goes into a LOCK-
OUT mode as the result of a system error. When
switched to the OFF position while the appliance is
operating, the system will shut down.
ON Position:
The appliance will ignite and run continuously at
is possible.
The IFT-ECM 2.0 has a safety feature that will
9 hours of continuous operation in the ON
position.
Remote Position:
The remote position allows operation of the
appliance from a wired wall switch, IFT-RC400
or IFT-RC150 remote controls. The IFT-ECM 2.0
switch must be in this position to pair the IFT-ECM
2.0 with the IFT-PACM 2.0 (if installed), and/or
IFT-RC400 and IFT-RC150 remote controls. See
the IFT-RC400 or IFT-RC150 installation manual
for detailed instructions on pairing the IFT-ECM 2.0
with the remote controls. After successfully pairing
a IFT-RC400, all installed accessories can be
controlled by the IFT-RC400 (see IFT-RC400 user
manual). The RC150 allows the user to turn ON/
Cold Climate mode if desired. The IFT-ECM 2.0 has
a safety feature that will automatically shut down
without receiving a command from the IFT-RC400 or
IFT-RC150.
2. If multiple control options are installed, the IFT-ECM
2.0 will respond to the last command from the wired
wall switch, IFT-RC400 or IFT-RC150. The wired wall
switch is NOT available if a Power Vent is used.
3. The Pilot button on the IFT-ECM 2.0 activates the Cold
ambient conditions. To activate the Cold Climate
IFT-ECM 2.0 Detailed Operating Instruction
press and hold the Pilot button for one second and
pressed to activate. To turn off Cold Climate, press
and hold the Pilot button for one second and release.
paired with the IFT-ECM 2.0, this feature can also be
activated with the IFT-RC400 and/or IFT-RC150.
4. An IFT-ECM 2.0 reset is required if the module is in a
lock-out condition. When this occurs, the appliance is
shut down and the IFT-ECM 2.0 status indicator LED
will be blinking a RED/GREEN error code along with a
one-time audible double- beep. If the IFT-ECM 2.0 is in
a lock-out condition, refer to the troubleshooting chart
to interpret the error code and take corrective action as
required. To reset the IFT-ECM 2.0 after a lock-out error
:
Figure 12. IFT-ECM 2.0
LED
INDICATOR
PAIRING
HOLE
RUBBER CAP
NG/LP SELECTOR
SWITCH
TOP VIEW
WIRE LEAD FROM REGULATOR
(SEE SIDE VIEW)
6VDC ADPTER
CONNECTION
50/30
SELECTOR
SWITCH
WI-FI MODULE
RF-MODULE
IGNITION LEAD
SPARK LEAD
3 POSITION SWITCH
CONNECT WIRE LEAD
FROM REGULATOR HERE
SIDE VIEW
CONNECT 6 PIN HARNESS HERE
ODS
CAUTION! Risk of burns! Appliance surfaces are hot
when operating and during cool down. Use care and wear
gloves when opening the front and accessing compo-
nents inside the appliance.