Using AptusLX 8.7.5 Data 2 1 3 No. Item Description 1 Data Sets the data settings. 2 Routing Config 3 Port/Protocol Forwarding Selects the data route type (None, Satellite Only, WAN Only). Click the Apply button to apply the settings to the system. Displays the port/protocol forwarding list. • Plus icon: To create new ports, click the plus icon. Then the pop-up window is opened. Enter the details, then click the Update button. The created ports are displayed on the list.
FB250 - Marine Satellite Communication System 8.7.6 Satellite 2 1 3 No. 1 2 Item Description Satellite By default, the terminal is set up to automatically find the most appropriate satellite to connect to (“Auto” mode). However, if you are located in an area with more than one BGAN satellite available, you can select the satellite you prefer to use when registering on the BGAN network. Select Satellite Select the satellite you prefer to use.
Using AptusLX 8.7.7 SMS 2 3 4 1 No. Item Description 1 SMS The BGAN system provides a Short Messaging Service (SMS) for sending and receiving SMS messages (Standard 3G, up to 160 characters per SMS) to and from the terminal. 2 SMS Inbox All received SMS messages are stored in the inbox. Unread messages are marked with a New icon. Click Delete ALL SMS Inbox to delete all messages in the Inbox. 3 SMS Outbox All sent messages are stored in the outbox.
FB250 - Marine Satellite Communication System 8.7.8 Service Profile 2 1 No. 1 Item Description Service Profile A profile is a collection of Quality of Service (QoS) settings and other settings defining the mode in which data is transmitted on an interface. For example, a profile is used to define whether a connection should be a Standard or Streaming connection. You can select between a number of predefined profiles or define your own profiles for your data transmission.
Using AptusLX No. Item Description - 2 Profile List - Use Usim Default APN: Set whether to use the default APN value of USIM or not (Enable/Disable). The APN is taken from the SIM card. This is the recommended option, unless you have special requirements. Use Defined APN: When you want to use a user-defined APN value, enter the APN value. APNs are provided from the Airtime Provider.
FB250 - Marine Satellite Communication System 8.7.9 Service User Group 2 1 No. 1 Item Description Service User Group The system can be organized in service user groups with different setup and different access rights. Each service user group has a service profile that determines how the users connect to the Inmarsat BGAN network. The network user groups can allow or restrict certain services for different users. NOTE: For F4-A250-S, the maximum Streaming bit rate is 128 kbps.
Using AptusLX 8.7.10 Device Classification 2 1 No. 1 Item Description Device Classification Register the MAC address of the device for using the data service, and assign a service user group to the device. Displays device classification list and information. 2 Device Classification List • Edit button: to edit the profile, click the edit button. Then the pop-up window is opened. Enter the details, then click the Update button. Click Delete button to delete it in the list.
FB250 - Marine Satellite Communication System 8.7.11 Traffic Flow Template (TFT) 2 1 No. Item Description Traffic Flow Template (TFT) is to assign different priorities to different types of traffic in order to optimize performance. 1 Traffic Flow Template When more than one type of traffic is needed, you must use both a primary and a secondary profile.
Using AptusLX 8.7.12 SIM 2 3 1 No. Item Description 1 SIM Sets the use of a PIN to access the terminal. 2 Require PIN Select Enable or Disable to use a PIN. • Enable: You must enter a PIN before you can change settings or make calls or data sessions. • Disable: You can access and use the terminal without entering a PIN. Click the Apply button to apply the settings to the system. The new PIN settings will take effect at next power on. 3 Change PIN Changes the PIN used to access the terminal.
FB250 - Marine Satellite Communication System 8.7.13 External GPIO 2 3 1 No. Item Description 1 External GPIO Select the external General Purpose Inputs/Outputs (GPIO) settings from the drop-down list. 2 Inputs Select the input settings from the drop-down list. 3 Outputs Select the outputs settings from the drop-down list.
Using AptusLX 8.7.14 Restricted Dialing 2 3 1 4 No. Item Description 1 Restricted Dialing Set up the terminal for restricted dialing. 2 Restricted Dialing Set whether to use restricted dialing or not (Enable/Disable). Click the Apply button to apply the settings to the system. Displays the restricted dialing list. • Plus icon: To create a new restricted dialing rule, click the plus icon. Then the pop-up window is opened. Enter the allowed numbers or masks in the entry box.
FB250 - Marine Satellite Communication System 8.7.15 Multi Voice 2 3 1 No. 1 2 Item Description Multi Voice Normally, the BGAN system only supports one call at a time per FB system. If you wish to have more simultaneous voice calls, you can add multi-voice to your airtime subscription. Multi Voice Sets the multi-voice service funcion. • Activate: Sets the multi-voice service by toggling the activation button (Enable/Disable).
Using AptusLX 8.7.16 NSD 2 1 No. Item Description 1 NSD A Network Service Device (NSD) is an Ehernet hardware device, identified by its unique MAC address. When a network device with dynamic IP address is connected to the terminal, it is automatically listed in the Terminal Type list. 2 Network Service Device Select the terminal type from the drop-down list. Click the Apply button to apply the settings to the system.
FB250 - Marine Satellite Communication System 8.7.17 MST 2 1 No. Item Description 1 MST Sets the Maritime Service Terminal (MST). Sets the maritime service funcion. 2 Maritime Service Terminal • MST Connection: Sets the maritime service by toggling the activation button (Enable/Disable). • Server: Enter the server ID. • Client: Enter the client ID.
Using AptusLX 8.8 Tools This menu sets and displays the Software Upgrade, Backup & Restore, Reset, Logs, Diagnostic, and Support function. 8.8.1 Software Upgrade 1 2 No. 1 2 Item Description Software Upgrade Upgrades antenna software firmware. Config Browse and select the package firmware file to upload and click the Upload button. The update may take a few minutes to complete. The upload time may vary due to a variety of factors such as the speeds of your network.
FB250 - Marine Satellite Communication System Package Update Procedures: 1. Browse and select the upgrade package file to upload. Click on the Upload button to transfer the Firmware package file (*.bin) to the BDU module. 2 1 2. The antenna firmware state will appear in the pop-up window. Check the current version and the new version. Click the Upgrade button. 3. During the upgrade process, the window will display process status. 4. If the firmware is successfully upgraded, it will display as Success.
Using AptusLX 8.8.2 Backup & Restore 1 2 3 No. Item Description 1 Backup & Restore Backs up user configuration files to PC and Restores the antenna settings. 2 Backup Saves user configuration files to PC. Click the Backup button to apply the settings to the system. 3 Restore Restores the antenna setting by using the setting files saved from the PC. Click the Restore button to apply the settings to the system.
FB250 - Marine Satellite Communication System 8.8.3 Reset 1 2 3 No. Item Description 1 Reset Resets the antenna system and factory reset. 2 Reset Click the Reset button to reset the antenna system. The user configuration is not reinitialized. 3 Factory Reset Click the Factory Reset button to initialize the antenna system. The user configuration is initialized.
Using AptusLX 8.8.4 Logs 2 1 No. Item Description 1 Logs Downloads the antenna log data. Logs Displays the antenna log list. • Download Log File: Any log data (.gz) within a month can be downloaded. Click the Download Log File button.
FB250 - Marine Satellite Communication System 8.8.5 Diagnostic 2 1 3 4 5 No. Item Description 1 Diagnostic Executes antenna diagnosis test to check the antenna status. 2 H/W (Hardware) Test Mode Activate Sets the hardware test function by toggling the activation button (Active/ Inactive). 3 Self Test 4 Self Test Result Displays the self-test result. ADU Diagnostic Executes the ADU diagnosis test to check each part of ADU status.
Using AptusLX Diagnosis Procedures: 1. Select the checkbox (full diagnosis test or single diagnosis test) before modifying the settings. Click on the Start button to run the diagnostic test. 2 1 2. Once the diagnosis starts, the page will indicate test status. It should take a few minutes to complete the test. 3. After the diagnosis is completed the system shows the diagnosis results of each item.
FB250 - Marine Satellite Communication System No. Item Description Displays the diagnosis code. 1 Diagnosis Code Code Test 101 The data communication between the antenna and the BDU is tested. 102 The azimuth axis is tested. 103 The elevation axis is tested. 104 The cross-level axis is tested. 105 Not Available 106 Not Available 107 The rate sensor is tested. 108 Not Available 109 Not Available 110 The LNB / NBD is tested. 111 The LNB pol motor is tested.
Specification 8.8.6 Support 2 1 No. Item Description 1 Support Downloads the User Guide. 2 Manual The user guide file (.pdf) can be downloaded. Click the Download button.
FB250 - Marine Satellite Communication System Chapter 9. Specification 9.1 Technical Specification Above Decks Unit (ADU) ADU Height 295 mm (11.61") ADU Diameter Ø291 mm (11.45") ADU Weight 4.5 kg (9.92 lbs) (TBD) Rx Tx Frequency 1518.0 ~ 1559.0 MHz L-Band Gain 10.8 dB Frequency 1626.5 ~ 1675.0 MHz L-Band Gain 11.3 dB RF Output power 34.1 dBm Polarization RHCP (Rx and Tx) G/T -15.5 dB/K EIRP 15.
Specification GPIO 1 ea, (10 pins) General Purpose I/O Wi-Fi 1 ea, SMA Female External Wi-Fi Antenna On/Off switch 1 ea, Power Switch System Power Switch Reset 1 ea System Reset Ground 1 ea Grounding BDU Power Input 10.
FB250 - Marine Satellite Communication System 9.2 Environmental Specification Test Temperature (ADU) Temperature (BDU) Intellian Standard Operational IEC-60945 (-25°C to +55°C / Power On) Survival IEC-60945 (-40°C to +80°C / Powered On and a nonfunctional state) Storage IEC-60945 (-40°C to +85°C / Power off) Operational IEC-60945 (-25°C to +55°C) Survival IEC-60945 (-40°C to +80°C) Storage IEC-60945 (-40°C to +85°C) IEC-60068-2-30 Humidity Upper test Temp.
Warranty Chapter 10. Warranty 10.1 Warranty Policy Intellian systems are warranted against defects in parts and workmanship, these warranties cover THREE (3) YEAR of parts and TWO (2) YEAR of factory repair labor to return the system to its original operational specification. Warranty periods commence from the date of shipment from Intellian facility, or date of installation which is come sooner.
FB250 - Marine Satellite Communication System Chapter 11. Appendix 11.1 Appendix A. Tightening Torque Specification The material qualities of screws are standardized. Refer to the tightening torque N-m according to ISO 898/1. Bolt Size Tightening Torque (N-m) A2-70 (6.8) A4-80 (8.8) M4 1.5 2 M5 3 4 M6 5.1 6.8 M8 12.2 16.6 M10 25.2 33.1 M12 43.9 58.