Installing ADU
5.4 Mounting Antenna
The lower radome has an industry-standard mounting hole with four mounting points. This hole pattern is
compatible with other companies' mounting holes. Use the mounting holes to secure the antenna to the
desired mounting surface. Bring the provided Antenna Mounting Template and the ADU Bolt Kit from the
ADU package. Create the appropriate hole pattern in the desired mounting surface.
5.4.1 Mounting Antenna on Mast
Check the position of
A
the antenna's cable connector and BOW direction. Lift the antenna above the
mounting surface using hands and carefully put the antenna down in place. Before assembling bolts, apply
Loctite #263 to the bolt's threads to ensure the bolts are fastened rmly. Insert
B
the bolts and washers
from under the mast into the radome then fasten them to the nuts assembled inside the radome using the
torque wrench.
BOW
Use a torque wrench.
x Four Times
M6 Flat Washer
M6 Spring Washer
M6 x 25L Hex. Bolt
A
B
Figure 12: Mounting Antenna on Mast
5.4.2 Mounting Antenna on Pole (Optional)
Intellian offers the Antenna Pole Mount Kit (separate purchase) to mount the antenna on the pole. The kit is
designed to work on 40A pole. The kit has mounting holes that match the inner hole with M6 bolts on the
bottom of the antenna.
Name Diameter (inch) External Diameter (mm)
40A
48.6
1. When mounting antenna on the 40A pole, the 40A pole bushing needs to be installed inside pole tube
additionally.
A
The position between holes of the pole tube must be aligned with the BOW direction.
Place the 40A pole bushing inside pole tube, then tighten them on the top end of the 40A pole using
bolts. Before assembling bolts, apply Loctite #263 to the bolt's threads to ensure the bolts are fastened
rmly.
*The pole tube Inner Diameter is Ø52 mm.
Figure 11: Installing 40A Pole Bushing inside Pole Tube
Use a torque wrench.
x Three Times
M12 x 12L
Socket Set Screw
40A Pole Bushing
*Pole Tube
40A Pole
BOW
A