User guide
FLX-44 Installaon Guide
27
Roung Commands
RS232 and TCP/IP Commands
RS232 Sengs: 9600 baud, 8 Data bits, 1 Stop bit, Parity = None
TCP/IP Sengs: User dened IP address (default IP address: 192.168.0.178), port 8080
There is either a period (.) or a semicolon (;) at the end of each command. These characters must be present for
the command to process correctly.
There are no spaces between any of the characters in the command string.
xx = Input Number (input 2 would be 02)
yy = Output Number (output 3 would be 03)
<CR> = Carriage return (Hex 0D)
<LF> = Line Feed (Hex 0A)
Descripon Command Response
Route input xx to output yy
xxByy. AV: xx->0yy<CR><LF>
Route input xx to all outputs
xxAll. xx To All<CR><LF>
Route inputs to corresponding outputs
All#. All Through.<CR><LF>
Route input xx to mulple outputs yy
Number of outputs is unlimited; each
output must be separated by a comma (,)
xxByy,yy. xxVyy,yy<CR><LF>
Turn o all outputs
All$. All Closed.<CR><LF>
Turn o specic output yy
yy$. AV: yy Closed. <CR><LF>
Output yy roung status
Statusyy. V: xx->0yy<CR><LF>
Roung status of all inputs.
Status.
V: xx->0yy<CR><LF>
(Repeang sequence starng with
output 1, output 2, etc�)
02All.
Route Video and Audio from input 2 to all outputs
04$.
Turn o Video and Audio for output 4
02B03.
Route Video and Audio from input 2 to output 3
03B02,04.
Route Video and Audio from input 3 to outputs 2 and 4
Examples: