User's Manual

Intelibs, Inc Proprietary and Confidential Page 34
34
OUT LWR
Sets lower limit of downlink output power, and
displays its value and alarm status
ALC
Sets ALC (Automatic Level Control) functions
activation level, and enable/disable ALC.
ASD
Sets ASD (Automatic Shut Down) functions
activation level, and enable/disable ASD.
Table 4-4 Rx-MAIN/MIMO
Status group
Parameters
LED
Clickable
Description
Protection
On/Off
Enable/disable uplink Protection function. In
order to protect RU system from unexpected
uplink high input power. If uplink input signal is
higher than IN UPRlevel, RU system is shut
downed and the LED color turns to red color.
Pilot On/Off
Enable CW signal. It is used for uplink gain setting.
IN PWR
Uplink input power
IN UPR
Sets upper limit of uplink input power, and
displays its value and alarm status
ATT Sets uplink attenuation, and displays its value.
OUT PWR Uplink output power
Center
Indicates a frequency of pilot signal, and this
value is changed automatically as downlink center
frequency changed.
RX AGC
Enable uplink path AGC (Automatic Gain Control)
function, and sets its level.
AGC ATT
Attenuation value of uplink path AGC function
AGC Period Time period of uplink path AGC function
Table 4-5 HPA-MAIN/MIMO
On/Off
Enable downlink HPA (High Power Amplifier)
function, and indicates its status.
OVTMP
Indicates current alarm status of HPAs over-
temperature.
OVPWR
Indicates current alarm status of HPAs over-
Power.
VSWR
Indicates current alarm status of HPAs VSWR
(Voltage Standing Wave Ratio).
OUT PWR
Indicates HPAs output power level.
OUT UPR
Indicates current alarm status of HPAs output
power upper limit, and sets upper limit value.
OUT LWR
Indicates current alarm status of HPAs output
power lower limit, and sets lower limit value.
ALC
Indicates ALC (Automatic Level Control) functions
current on/Off status, and sets ALC activation
level.
ASD
Indicates ASD (Automatic Shut Down) functions
current on/Off status, and sets ASD activation
level.