User's Manual

Intelibs, Inc Proprietary and Confidential Page 33
33
Table 4-2 General/Environment/Optic
Status group
Parameters
LED
Settable
Description
Version
Firmware Version of the DAS system
DAS Type The type of the DAS system
Name
Sets following information of the DAS
- Name
- Model Number
- Serial Number
Time/UpTime Current time or Up-time
User Connect
Connection status with the DAS
PSU
Status of Power Supply Unit
TMPCUR
Current chassis temperature of the DAS system
TMPUPR
Sets temperature upper limit, and display its value
and alarm status.
LDPWR
Current output power of LD (Laser Diode) of optic
module connected to RU.
LDLWR
Sets the lower limit of output power of LD, and
display its value and alarm status.
PDPWR
Current input power of PD (Photo Detector) of
optic module connected to RU.
PDLWR
Sets the lower limit of input power of PD, and
display its value and alarm status.
Table 4-3 Tx-MAIN/MIMO
Status group Parameters
LED
Clickable Description
MAIN Path
Selects MAIN channel
MIMO Path
Selects MIMO channel
PLL
PLLs Alarm status
CFR ON
ON/OFF status and control of CFR (Crest Factor
Reduction) function
CFR Ver. Version of CFR function currently working
ATT
Sets ATT value to control downlink Gain.
ATT = USR ATT + ALC ATT
USR ATT
Used for downlink Auto Gain Control and fine
tuning of gain.
ALC ATT
Downlink ALC (Automatic Level Control)
attenuation value. Available when ALC function is
activated.
IN PWR
Downlink input power from MHU
Center
Sets a center frequency of downlink AWS band.
TC ATT
Displays downlink temperature compensation
attenuation value, and enable/disable downlink
temperature compensation.
HPA On/Off Enable/disable downlink HPA (High Power Amp).
OUT PWR
Downlink output power
OUT UPR
Sets upper limit of downlink output power, and
displays its value and alarm status