User's Manual
Intelibs, Inc. Proprietary and Confidential Page 33
33
4.2.2 Parameters details in RHU window
Group
Description
Version: Firmware Version
S/N: RHU Serial Number
Unit Name: RHU
Model Number: Model number of RHU
Up Time: operating time and date
User Connect: Connection status between Laptop and
RHU
PWR Alarm: DC power alarm
Temp: Current temperature of the inside of unit
Upper Temp: set the upper threshold value of
temperature(Value) and alarm status (LED)
Band screen selection TAB.
Down Link monitoring and control item of each band
Path ON/OFF: DL Path ON/OFF function
PLL: PLL lock alarm indicator
IN PWR: DL input power level coming from ANT
OUT PWR: DL output power level transmit to OMU
IN UPR: DL input upper limit value and alarm
IN LWR: DL input lower limit value and alarm
ATT 1&2: DL attenuation value for the DL gain control
ALC: Auto level limit control value and on/off button
AGC : Auto gain control level and on/off set button
TC ATT: Temperature compensation Attenuation and
On/Off set button
Up Link monitoring and control item of each band
Path ON/OFF: UL Path ON/OFF function
PLL: PLL lock alarm indicator
IN PWR: UL input power value
OUT PWR: UL Output power value
IN UPR: UL input upper limit value and alarm
IN LWR: UL input lower limit value and alarm
ATT 1 & 2: UL Attenuation value for the UL gain control
ALC: Auto level limit control value and on/off set
AGC : Auto gain control level and on/off set
Shutdown: Auto shutdown level value set
TC ATT: Temperature compensation Attenuation and
On/Off button