User's Manual
Table Of Contents
- 1 Introduction
- 2 Product Description
- 3 Appendix I. Ancillary Devices – Antenna, Cable and other Passive Device
- 4 Human RF Exposure – Maximum Permissible Exposure Evaluation
Intelibs, Inc Proprietary and Confidential Page 12
12
2.4.3 RF specifications
Table 2-6 Dual band specifications
2.4.4 Power Specifications
Table 2-7 Power specifications
Item
Specification
Rated Input Voltage
12 V DC
Permissible range
Tolerance ±10%
Power consumption
30
W, maximum
27 W, typical
Item
Specification
Remarks
Downlink Frequency
869 ~ 894 MHz, 1930 ~ 1990 MHz
Uplink Frequency 824 ~ 849 MHz, 1850 ~ 1910 MHz
Operating Bandwidth
Cellular: 25MHz BW
PCS: 60MHz BW
DL Output Power
+26dBm/composite @ANT Port
Dual Band Output Power
Optical wavelength
SRU: DL 1310/UL 1550nm
WDM included
Optic Module Gain
0dB w/ passive device loss
Optic Module Gain FHU ~ SRU
Available optical fiber loss 2dBo (2Km) max. Including connector loss.
Gain ripple over each band
2 dB Peak to Peak
Gain flatness over 25MHz BW
Gain flatness over Dual Band
+/- 2dB(4dBp-p)
Gain flatness of 850/1900MHz
Attenuator Control Range
0 ~ 30dB
Optic loss Compensation
Gain Control Step Size 1 dB ±0.7 dB tolerance at 0 ~ 25dB
Input VSWR 1.5: 1 Max. All of RF Port
Frequency Stability ±0.01 ppm
System Delay 500nsec max.
EVM 5% max.
Rho
0.998 min.
Spurious Emissions
Comply to 3GPP, 3GPP2 and FCC
Rx Noise Figure
5 dB @UL Gain 40dB
@ Room temperature
Rx max. input level
-40dBm
CW -30dBm can be receivable
System Gain
DL 45~47dB/UL 50~52dB
Gain ±2dB @-20~50°C