Tus neeg siv phau ntawv

9
6. Test
Once installed and energized, walk in the area to be protected simulating a possible intrusion. Observe if the sensor is
able to detect your movements during the journey, by lighting the lens. Adjust its sensitivity if necessary or reposition the
sensor installation.
If the alarm control panel used is Intelbras, put it in test mode, this way it will not be necessary to observe the LED, as the
control panel will indicate the sensor’s operation through siren beeps.
7. Conguring the IVP 4000 smart sensor (for board version
4410030/3 and rmware 1.3.2 or earlier)
7.1. Sensitivity adjustment of the IVP 4000 smart sensor
The SENS jumper (JP1) is used to control the detection sensitivity. With jumper JP1 in position 1 the sensor provides
maximum sensitivity. With jumper JP1 in position 2 the sensor provides minimum sensitivity. Factory default: position 1.
7.2. Setting the operating mode of the IVP 4000 smart sensor
Via the ECO/CONT jumper (JP2), select between intelligent continuous mode and economy mode. Factory default economy
mode.
With jumper JP2 in position 2 (ECO) the sensor will operate in economy mode, working as follows: after power-up, the
sensor will work continuously for 30 minutes so that the installer can make all the adjustments to the sensor. After this
time the sensor enters economy mode.
» Economy mode operation: the sensor will detect and transmit 1 (once) to the control panel, after this trigger, the
sensor enters the economy mode (low consumption mode without detection). In this mode, the sensor will detect and
transmit to the alarm center only after 2 (two) minutes without movement in the environment. After 2 (two) minutes the
sensor will be able to detect and transmit the event to the central alarm. For a better understanding of Economy mode,
see the timeline below.
30 min
After placing
the battery the sensor
stays in stabilization
and the LED stays
blinking. Note: do not
register the
sensor on switch in this
period, wait 50 sec so
that the sensor enter
mode continuous.
In this mode any
detection o LED
lights up and
generates firing.
No
detects
mode
Stabili-
zation
50 sec
Continuous
mode
Time the sensor remains on.
Economical mode
2 min
In this mode the
sensor detects the first
movement and gene
-
rates a trigger, howe-
ver it goes into hiber-
nation and detects
again after two minu
-
tes without movement
in the place, in the
hibernation period the
LED does not light.
In this 2 min
period, if there is
movement in
place, the sensor
waits for the last
movement to
start counting
down the two
minutes.
After 2 minutes of
the last movement
of the site, the
sensor detects and
generates a trip at
the control panel.