5.4. Low battery sensor
The IVP 4000 SMART sensor controls the battery level. If it is critical (equal to or below 2.5V), it will send the information
to the control panel.
If the sensor is congured in unsupervised mode (OOK) and the low battery signal is enabled in the control unit, the
information is sent during the trip. Otherwise, if the sensor is congured in supervised mode (FSK), low battery sending is
done during supervision and triggering.
Note:
consult the control panel manual to verify compatibility with low battery signaling and supervision.
To make the desired adjustments follow the steps below:
1. Open the IVP 4000 smart sensor;
2. Congure the jumpers according to the desired settings;
3. Take a trigger to effect changes to the sensor conguration.
Note: do not register the sensor in the control panel during the stabilization time, wait for it to start working in intelligent
or economical continuous mode.
To register the sensor code in the alarm control panel, check the procedure in the manual of the used alarm control panel
and trigger a trigger by moving in front of the sensor to complete its registration.
Jumper SENS (JP1)
Position Condition
1 Maximum sensitivity
2 Minimal sensitivity
Jumper SUPERV (JP3)
Position Condition
Closed No (Unsupervised)
Open Yes (Supervised)
Jumper INT/CONT (JP2)
Position Condition
1 Smart Continuum
2 Economic
Supervised
No/Yes