Tus neeg siv phau ntawv
6
4. Installing the IVP 4000 smart sensor
To install the sensor, carefully read the topic Care and safety and follow the procedure below:
1. Open the sensor front cover by pressing the sides.
2. With the help of a tool, drill a hole in the back cover for the screw.
3. Insert the CR123A battery and position the sensor in the desired location. The IVP 4000 smart does not need to be
installed with an articulator as it already has a 15° inclination angle.
5. Conguring the IVP 4000 smart sensor (for cards in version
4410030/4 and rmware 2.0.0)
After the sensor is properly installed, make the adjustments according to the information below:
5.1. Sensitivity adjustment of the IVP 4000 smart sensor
The SENS jumper (JP1) is used to control the detection sensitivity. With jumper JP1 in position 1 the sensor provides
maximum sensitivity. With jumper JP1 in position 2 the sensor provides minimum sensitivity. Factory default: position 2.
5.2. Setting the operating mode of the IVP 4000 smart sensor
Via the ECO/CONT jumper (JP2), select between intelligent continuous mode and economy mode. With jumper JP2 in
position 1 the sensor is in intelligent continuous mode. With jumper JP2 in position 2 the sensor is in economy mode.
Factory default: position 2.
Once energized, the sensor will operate in the test period for 15 minutes so that the installer can make all sensor positio-
ning adjustments. During this period, at any motion detection, the LED lights up and a trigger is generated. Then the sensor
will operate as congured mode.
» Intelligent Continuous Mode: the sensor takes a reading of the environment and generates a trigger for 3 move-
ments, after this trigger generation the sensor goes into hibernation for 2 minutes. During this period the indication LED
is not activated and no new triggers are generated, as a notication has just been sent to the switch. After the sleep time,
the sensor is monitoring the environment until detecting 3 more events.
Trial period
15 min
Period of
stabilization
Time the sensor remains on
Smart Continuous Mode
2 min
After inserting
the battery,
the LED is
blinking and
there is no
detection.
At any detection
the LED lights
up and
generates a
trigger.
The sensor detects (lights the
LED and generates a trigger) for
the next 3 movements, after
which it goes into hibernation.
During this period the
LED does not light and
no new triggers are
generated.
After the
hibernation time,
the sensor returns to
detect and generate
triggers in the
central, starting the
cycle again.