User Guide
32
External number
☞
, w
ait for tone or confirmation prompt.
Factory setting
: extension 200 set as doorphone attendant.
3.2
CALL LOGGING
A serial printer is required to print the call logging statement:
- parellel printer
(you need the parallel kit see item
4.2.10
);
The CDR call firmat is displayed as follows :
line extension Number time duration date
E 02 208 13:15:05 00:12:30 19/01/98
E 01 NA 14:20:02 00:01:00 19/01/98
E 04 218 0482472600 13:15:00 00:12:30 10/01/97
E 01 ID 0482345678 16:30:05 00:00:00 19/01/98
E 04 215 0482819547 1 14:20:00 00:06:30 20/05/98
04 228 0115491234 13:15:10 00:12:30 18/01/97
01 232 2819500 13:19:30 00:01:20 18/01/97
01 PT1 2345678 16:30:05 00:30:00 19/01/98
01 AE1 2819500 09:45:20 00:01:08 20/01/98
01 CM 2472600 13:45:00 00:48:30 20/01/98
02 212 28196600 3 11:30:45 00:03:15 20/01/98
Incoming calls
:
-
E (incoming call);
-
NA (not answered);
-
0482472600 ( incoming number through caller ID );
-
if call classification is activated, the row between number and time will indicate the
classification code. see
item 2.12.
Outgoing calls
:
-
All outgoing call numbers will be registered;
-
PT 1 and PT2 ( calls originating from doorphone 1 and 2 );
-
AE1 or AE2 ( emergency calls 1 or 2);
-
CM ( calls using a modem );
-
2 digit number ( displayed between number and time when calls are
-
made using private code);
-
serial printer is required for printing call logging.
3.2.1
Incoming Call Logging
Answered call
Activate
☞
, w
ait for tone or confirmation prompt.