User Guide
21
» Program DNS servers for Ethernet
Enter + 815 + S + Enter, where S = 1 or 2 (Server 1 or Server 2).
After the command, type the DNS1 server number and press the
Enter
key to conrm.
» Program Ethernet heartbeat interval (link test)
Enter + 816 + TTM + Enter
, where TTM = time interval ranging from 000 to 255 minutes (default: 5 minutes).
» Exit programming mode with the installer’s password
Installer password (default:
9090
).
» Check connection to IP receiver service
Press the Menu key, navigate with the arrow keys, access the Connections option and check that the
Eth: IP1 and/or IP2
option checkbox is enabled. If so, the center connects via Ethernet to the IP receiver software through the enabled IPs.
Via GPRS connection
» Program monitoring account
Enter + 15 + PP + Enter
, where PP = partition from 01 to 16. After the command: type the 4-digit monitoring account
number (0 to 9 or the letters B, C, D, E and F) and press the
Enter
key to conrm. If the center is not partitioned, use the
partition as
01.
» Program the report mode
Enter + 17 + AAA + Enter.
AAA = indicates in which mode the alarm center will operate, where 000: deactivated, 400: regular IP and 600: dual IP.
» Program communication priority (GPRS only)
Enter + 19 + 1 + Enter.
» Program destination IP
Enter + 801 + I + Enter
, where I = 1 or 2 (destination IP 1 or destination IP 2).
After the command type the IP number of the monitoring company 1 (example: 192.168.001.100) and press the
Enter
key to conrm.
» Program IP network communication port
Port 1 = Enter + 802 + 1 + 4-digit port number + Enter.
Port 2 = Enter + 802 + 2 + 4-digit port number + Enter.
» Program the destination domain name (DNS)
If you do not want to use the DNS, go to the next command; otherwise, type:
Enter + 803 + 1 + Enter.
After the command type the DNS domain name and press the
Enter
key to conrm.
» Program monitoring options via IP
Enter + 830 + Enter.
After the command, using the keys on the keyboard, enable the desired option from 1 to 4, where:
» 1 = enables the sending of events to the monitoring company 1.
» 2 = enables the sending of events to the monitoring company 2.
» 3 = Enables the domain name (DNS) of the monitoring company. 1.
» 4 = Enables the domain name (DNS) of the monitoring company. 2 and press the
Enter
key to conrm.
» Program login
Enter + 822 + O + Enter
, where O = 1 or 2 (operator 1 or operator 2).
After the command, type the user name (according on the operator used) and then press the
Enter
key to conrm.
» Enable chips
Enter + 832 + Enter.