User Guide

17
On input partition
Enter + 516 + GP + Enter
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
Permission to activate and/or deactivate the oninput
Enter + 518 + Enter
Tecla 2 – Permission to activate
Tecla 3 – Permission to deactivate
3.6. Partition
Enable partition
Enter + 510 + Enter + Select option 1 + Enter.
Zone partitioning
Enter + 01 + ZZ + PP + Enter.
ZZ = zone from 01 to 64.
PP = partition from 01 to 16.
» Dene permission for password partitioning
Enter + 21 + NU + GP + Enter.
NU= user number from 01 to 96.
GP = group of partitions, with partitions 01 to 10 in group 0 and partitions 11 to 16 in group 1.
Attention: In addition to the programming points mentioned above, it is necessary to create/dene user passwords
(topic
3.4. Passwords)
as well as register wireless controls for access
(topic Remote Control)
. It is also necessary to dene the
partitioning of keyboards
(topic Keyboard)
and sirens
(topic Wireless Sirens).
3.7. Timings
Input timing
Enter + 42 + PP + TTS + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
TTS = time from 000 to 255 seconds.
» Beep adjustment on input timing
Enter + 542 + A + Enter.
A= 0 - Disabled
1. Low
2. Medium
3. High
Output timing
Enter + 44 + PP + TTS + Enter.
PP = partition from 01 to 16 (center without partition, use PP = 01).
TTS = tempo from 000 to 255 seconds (beeps will be emitted only through the keyboard and not through the integrated
siren).