User Guide

12
» Repeater rmware verication
Enter + 644 + RR + Enter.
RR = 2-digit repeater number.
Route change by command
» Search for new route sensors
Enter + 544 + ZZ + Enter.
ZZ = 2-digit zone number.
» XAT 8000 new route search
Enter + 545 + TT + Enter.
TT = 2-digit keypad number.
» PGM 8000 new route search
Enter + 547 + PP + Enter.
PP = 2-digit PGM number.
Note: function available for devices from version 2.0.0 onwards.
» Register Actuator PGM 8000
Enter + 623 + PGM + Enter + Actuate the Actuator by pressing the synchronization key.
PGM = Actuator number from 01 to 16.
» Delete PGM 8000 actuator
Enter + 723 + PGM + Enter.
PGM = Actuator number from 01 to 16.
Firmware verication of PGM 8000 actuators
Enter + 646 + PP + Enter.
PP = 2-digit PGM number.
Note: function available for devices from version 2.0.0.
» PGM 8000 actuator functions
Enter + 50 + PGM + Enter + M + E + Enter.
PGM = PGM number from 01 to 16.
M = PGM operation mode from 0 to 9 (0 = on/off, 1 to 8 = pulse and 9 = programmed time).
E = Event that actuates PGM from 00 to 13.
00 External actuation (applications)
01 Password actuation (passwords from 51 PGM01 to 66 PGM16)
02 System activation
03 System deactivation
04 Medical emergency:
05 Event communication failure
06 N/A
07 Siren problem:
08 Trigger
09 Trigger or silent panic
10 Fire zone triggering:
11 Zone 1 opening
12 Remote control
13 Activation / deactivation by time
» Time programmed for PGM 8000 to remain on
Enter + 560 + PGM + T + Enter.
PGM = PGM number from 01 to 16.
T = Time from 01 to 99 minutes.