52 ITP700 Debug Port Design Guide
Table 32. ITP700 LVDPA Execution Signal AC Electrical Characteristics
Signal Parameter Min Max Unit Note
Setup 400 ps 1 BPM[5:0]#, RESET
Hold 200 ps 1
Rise Time 5 ns 2
Fall Time 5 ns 2
Period 5 15 ns 3
Time High 2.2 ns
BCLK(p/n)
Time Low 2.2 ns
Rise Time 1 4 ns 2, 4 BPM5DR#
Fall Time 8 15 ns 2, 4
NOTES:
1. With respect to BCLK(p/n).
2. Measured from 20% to 80% of transition.
3. Specification for valid synchronous operation of the ITP. Asynchronous operation has no Max
specification but shares the Min specification listed.
4. Measured into a load to 1.5 V of 50 and 35 pF to GND.