Specification Update

Monthly Specification Update Enterprise Platforms and Services Marketing
14
Implication You may not be able to wake system through onboard NIC port.
Status This issue will be fixed in Intel
®
LAN driver version 17.4 and later release
Workaround None.
27.
S3 feature may not be function on P4000CR System with PBA
(G21602-302)
Problem The PBA G21602-302 with Bios 01.02.0005 may not enter S3 status even
upgrade to later Bios release with normal capsule .
Implication S3 feature may not work on the system.
Status This issue is fixed by Bios 01.03.0001.
Workaround Upgrade to new Bios with recovery capsule.
28.
System only reports the first occurrence of power redundancy lost
events
Problem The integrated platform management subsystem will only report the first
occurrence of a power redundancy lost event. Any additional power
redundancy lost events that may occur after the initial event, will not be
reported unless an AC cycle of the server is performed.
Implication With the first power redundancy lost event detected, the system status LED will
change the state to flashing Green and the system event log will display the
event as shown below.
Power Unit, Pwr Unit Redund (#0x2) Informational event: Pwr Unit Redund
reports full redundancy has been lost. Integrated BMC - LUN#0 (Channel#0)
After hot swapping the faulty power supply, which would change the state of
the system back to normal (system status LED goes back to solid Green), the
system will NOT report any further power redundancy lost events, until an AC
cycle of the server is performed.
Status This issue was fixed in BMC release 1.17.4151.
29.
The MAC address of Dual Port Intel® X540 10GbE I/O Module
(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all zero
Problem With BIOS R01.06.0001, the MAC address of Dual Port Intel® X540 10GbE I/O
Module(AXX10GBTWLIOM and AXX10GBTWLHW) in BIOS displays as all
zero.