Service Guide
Hardware Installations and Upgrades
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 57
Figure 71. 8x2.5” Hot Swap Backplane Cable Connections
7. Install the front bezel. For instructions, see “Installing the Front Bezel (Pedestal Only)”.
8. Install the air duct if the air duct is removed. For instructions, see the Quick Start User’s Guide or
Service Guide provided with your Intel
®
server/workstation board.
9. Install the chassis cover. For instructions, see “Installing the Chassis Cover”.
10. Plug all peripheral devices and the AC power cable into the server.
11. Power up the server.
Removing and Installing the Hot-swap HDD EMI Shield
/
NOTE
This procedure applies only to the Intel
®
Server System P4000IP family with 8x2.5” hot-swap hard disk
drive cage configuration.
Removing the Hot-swap HDD EMI Shield
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the front bezel. For instructions, see “Removing the front bezel (Pedestal Only)”.
5. Remove the 8x2.5” Hot-swap HDD cage. For instructions, see “Removing 8x2.5” Hot-swap Hard Disk
Drive Cage with Backplane”.