Service Guide
Hardware Installations and Upgrades
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 37
Replacing the Fixed Fan
/
NOTE
Please pay attention to the fan cable connector color. The fan with blue connector should be installed in
fan 2 bracket and the fan with white connector should be installed in fan 1 bracket. The fan numbering is
inscribed on the chassis.
This procedure applies only to the Intel
®
Workstation System P4000CR family with fixed fan configuration.
Removing the Fixed Fan
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the air duct if the air duct is installed. For instructions, see the Quick Start User’s Guide or
Service Guide provided with your Intel
®
server/workstation board.
5. Disconnect the appropriate fan power cable from the server board (see letter A).
Figure 44. Disconnecting the fan power cable from the server board