Service Guide

Hardware Installations and Upgrades
Intel
®
Server System P4000IP and Intel
®
Workstation System P4000CR Service Guide 97
Installing Alternate Serial Port
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, see “Removing the Chassis Cover”.
4. Remove the alternate serial port knockout by pressing the knockout from inside the chassis.
5. Install the serial port on the rear panel of the chassis and connect the cable to the Serial B Connector
on your motherboard.
Figure 137. Installing the Alternate Serial Port Knockout
Installing and/or Removing a Expander card
Installing the Expander card
1. Observe the safety and ESD precautions at the beginning of this book.
2. Power down the server and unplug all peripheral devices and the AC power cable.
3. Remove the chassis cover. For instructions, “Removing the Chassis Cover”.
4. Remove the fans. For instructions, seeRemoving the Fixed Fan” or Removing the Hot-swap Fans”.
5. Remove the Fixed HDDs or Hot swap drive cages. For instructions, see “Remove Fixed Hard Drives”,
or “Remove 8x3.5 Hot swap Drive Cage Assemble”, or “Remove 8x2.5 Hot swap Drive Cage
Assemble”