Technical Product Specification

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.4 Intel order number G34153-004
133
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
69h
-
6Bh
Chassis-
specific
Microcontroller
16h
Discrete 0Ah
04- transition to Off
Line
Degraded
Trig
Offset
X
Processor 1 Status
(P1 Status)
70h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 2 Status
(P2 Status)
71h
All
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 3 Status
(P3 Status)
72h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 4 Status
(P4 Status)
73h
Platform-
specific
Processor
07h
Sensor
Specific
6Fh
01 - Thermal trip
Fatal
As and
De
Trig
Offset
M
X
07 - Presence
OK
Processor 1
Thermal Margin
(P1 Therm Margin)
74h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 2
Thermal Margin
(P2 Therm Margin)
75h
All
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 3
Thermal Margin
(P3 Therm Margin)
76h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 4
Thermal Margin
(P4 Therm Margin)
77h
Platform-
specific
Temperature
01h
Threshold
01h
-
-
-
Analog
R, T
A
Processor 1
Thermal
Control %
(P1 Therm Ctrl %)
78h
All
Temperature
01h
Threshold
01h
[u] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
Trig
Offset
A