Technical Product Specification

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.4 Intel order number G34153-004
131
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
SAS Module
Temperature
(SAS Mod Temp)
2Dh
Platform-
specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Exit Air
Temperature
(Exit Air Temp)
2Eh
Chassis
and
Platform
Specific
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Network Interface
Controller
Temperature
(LAN NIC Temp)
2Fh
All
Temperature
01h
Threshold
01h
[u,l] [c,nc]
nc =
Degraded
c = Non-
fatal
As and
De
Analog
R, T
A
X
Fan Tachometer
Sensors
(Chassis specific
sensor names)
30h
3Fh
Chassis
and
Platform
Specific
Fan
04h
Threshold
01h
[l] [c,nc]
nc =
Degraded
c = Non-
fatal
2
As and
De
Analog
R, T
M
-
Fan Present
Sensors
(Fan x Present)
40h
4Fh
Chassis
and
Platform
Specific
Fan
04h
Generic
08h
01 - Device inserted
OK
As and
De
-
Triggered
Offset
Auto
-
Power Supply 1
Status
(PS1 Status)
50h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive Failure
Degraded
03 - A/C lost
Degraded
06 Configuration
error
OK
Power Supply 2
Status
(PS2 Status)
51h
Chassis-
specific
Power Supply
08h
Sensor
Specific
6Fh
00 - Presence
OK
As and
De
Trig
Offset
A
X
01 - Failure
Degraded
02 Predictive Failure
Degraded
03 - A/C lost
Degraded
06 Configuration
error
OK