Technical Product Specification

Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS Appendix B: BMC Sensor Tables
Revision 1.4 Intel order number G34153-004
127
Full Sensor Name
(Sensor name in SDR)
Sensor
#
Platform
Applicability
Sensor Type
Event/Reading
Type
Event Offset Triggers
Contrib. To
System
Status
Assert/De-
assert
Readable
Value/
Offsets
Event
Data
Rearm
Stand-
by
Voltage Regulator
Watchdog
(VR Watchdog)
0Bh
All
Voltage
02h
Digital
Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
X
Fan Redundancy
1
(Fan Redundancy)
0Ch
Chassis-
specific
Fan
04h
Generic
0Bh
00 - Fully redundant
OK
As and
De
Trig
Offset
A
01 - Redundancy lost
Degraded
02 - Redundancy
degraded
Degraded
03 - Non-redundant:
Sufficient resources.
Transition from
redundant
Degraded
04 - Non-redundant:
Sufficient resources.
Transition from
insufficient.
Degraded
05 - Non-redundant:
insufficient resources.
Non-Fatal
06 Non-Redundant:
degraded from fully
redundant.
Degraded
07 - Redundant
degraded from non-
redundant
Degraded
SSB Thermal Trip
(SSB Therm Trip)
0Dh
All
Temperature
01h
Digital
Discrete
03h
01 State Asserted
Fatal
As and
De
Trig
Offset
M
X
IO Module
Presence
(IO Mod Presence)
0Eh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
-
SAS Module
Presence
(SAS Mod
Presence)
0Fh
Platform-
specific
Module/Board
15h
Digital
Discrete
08h
01 Inserted/Present
OK
As and
De
Trig
Offset
M
X