Technical Product Specification

Platform Management Overview Intel® Server Board S2600IP and Intel® Workstation Board W2600CR TPS
86 Intel order number G34153-004 Revision 1.4
No support for SOL or KVM for monitoring the entire boot process.
o Since BMC is initializing at the same time as BIOS, it will not be possible to have an
SOL or KVM session established from the beginning of the system boot.
FP status LED will behave differently (it will be off when on standby) rather than showing
fault conditions present at the time the system was powered down.
No beep code due to uninstalled CPU.
No monitoring of any sensors when on standby.
No detection/logging of any ThermTrip faults.
o These result as the system is shut down by HW so BMC will not be available to
detect that they occurred.
Sensor monitoring after DC power-on will be delayed by the time it takes BMC to
initialize its sensor subsystem (~15 to 20s), possibly losing SEL events or failing to
provide correct FP LED status LED indication.
Note: This delay occurs on each AC cycle even when EU Lot6 mode is disabled.
Chassis intrusion not detected when in standby