Technical Product Specification

Thermal and Acoustic Management Intel® Server System R2000IP Product Family TPS
34 Revision 1.1
4. Thermal and Acoustic Management
The Intel Server System R2000IP is designed to operate at external ambient temperatures in
compliance with ASHARE class A2. Working with integrated platform management, features
within the system are designed to move air in a front to back direction, through the system and
over critical components in order to prevent overheating and allow the system to operate with
best performance.
4.1 Thermal Operation and Configuration Requirements
To keep the system operating within supported maximum thermal limits, the system must meet
the following operating and configuration guidelines:
The system operating ambient is designed for sustained operation up to 35ºC (ASHRAE
Class A2) with short term excursion based operation up to 45ºC (ASHRAE Class A4).
o The system can operate up to 40ºC (ASHRAE Class A3) for up to 900 hours per
year
o The system can operate up to 45ºC (ASHRAE Class A4) for up to 90 hours per
year
o System performance may be impacted when operating within the extended
operating temperature range
o There is no long term system reliability impact when operating at the extended
temperature range within the approved limits.
Specific configuration requirements and limitations are documented in the configuration
matrix found in the Intel
®
Server System R2000IP product family Power Budget and
Thermal Configuration Guidelines Tool, available as a download online at Intel.com.
The CPU-1 processor + CPU heat sink must be installed first. The CPU-2 heat sink
must be installed at all times, with or without a processor installed.
Memory Slot population requirements
NOTE: Specified memory slots can be populated with a DIMM or supplied DIMM Blank.
Memory population rules apply when installing DIMMs.
o DIMM Population Rules on CPU-1 Install DIMMs in order; Channels A, B, C,
and D
1
. Start with1st DIMM (Blue Slot) on each channel, then slot 2. Only
remove factory installed DIMM blanks when populating the slot with memory.
o DIMM Population on CPU-2 Install DIMMs in order; Channels E, F, G, and H
1
.
Start with1st DIMM (Blue Slot) on each channel, then slot 2. Only remove factory
installed DIMM blanks when populating the slot with memory.
o The following system configurations require that specific memory slots be
populated at all times using either a DIMM or supplied DIMM Blank
System Configuration - 24x 2.5” hard drive bay or 12x 3.5” hard drive bay
configuration + Intel
®
Server Board S2600IP (16 DIMM server board)
Memory slot 2 populated on all memory channels
All hard drive bays must be populated. Hard drive carriers can be populated with a hard
drive or supplied drive blank.
With the system operating, the air duct must be installed at all times
In single power supply configurations, the 2
nd
power supply bay must have the supplied
filler blank installed at all times.
The system must be configured with dual power supplies for the system to support fan
redundancy.
Thermally, the system can support the following PCI add-in cards.