30  mPGA604 Socket Design Guidelines 
Table 5-1. Use Conditions Environment (Continued) 
Use Environment 
Speculative Stress 
Condition 
7 Year Life 
Expectation 
10 Year Life 
Expectation 
Fast, large gradient on/off to max 
operating temp. (power cycle or 
internally heated including power save 
features). 
Power Cycle  7,500 cycles  11,000 cycles 
Shipping and Handling.  Mechanical Shock 
50g trapezoidal 
profile; 170”/sec 
Velocity change; 11 
msec duration pulse 
3 drops / axis 6 
axis 
Shipping and Handling.  Random Vibration 
3.13 gRMS, random, 
5 Hz - 20 Hz .01 
g2/Hz sloping up to 
.02 g2/Hz 20 Hz - 
500 Hz .02 g2/Hz 
10 min / axis, 3 
axis 
5.1 Porosity Test 
5.1.1 Porosity Test Method 
Use EIA 364, Test Procedure 53A, Nitric acid test. Porosity test to be performed for 20 contacts, 
randomly selected per socket, five sockets. 
5.1.2 Porosity Test Criteria 
Maximum of two pores per set of 20 contacts, as measured per EIA 364, Test Procedure 60. 
5.2 Plating Thickness 
Measure various plating thickness on contact surface per EIA 364, Test Procedure 48, Method C or 
Method A. Test to be performed using 20 randomly selected contacts per socket, five sockets. No 
plating thickness measured shall be less than the minimum plating thickness specified in 
Section 3.9.3. 
5.3 Solvent Resistance 
Requirement: No damage to ink markings if applicable. EIA 364-11A. 
5.4 Solderability 
(Applicable for leaded sockets) Requirement: 95% coverage per ball/surface mount feature. EIA 
364, Test Procedure 52, Class 2, Category 3. Test to be performed on 20 randomly selected contacts 