Datasheet

Intel® Solid-State Drive DC S3500 Series (M.2)
2.3 Electrical Characteristics
Table 7: Operating Voltage for M.2 Form Factor
Electrical Characteristics
Intel SSD DC S3500 Series
80 GB
120 GB
340 GB
Operating Voltage for 3.3V (±5%)
Min
Max
3.13V
3.47V
Inrush Current (Typical Peak)
1
1.2 A, < 1 s
PLI Capacitor Charge Voltage
2
Average 34 Volts
Note:
1. Measured from initial device power supply application.
2. This is the voltage stored in the onboard capacitors used to save data held in the DRAM to NAND in the event of an unplanned power loss. As the
electronic components are exposed, care must be taken not to allow the M.2 drive to touch other electronic devices if removed from the circuit
until the capacitors have fully discharged. Allow 10 minutes for full discharge.
Table 8: Power Consumption for M.2 Form Factor
Specification Unit
Intel SSD DC3500 Series
80GB 120GB 340GB
Active Write - RMS Average
1
W
1.9 2.3 3.8
Active Write - Burst
2
W
2.1 2.5 4.5
Active Write - MAX Burst
3
W
3.7 4.2 5.9
Active Read - RMS Average
4
W 1.7 1.9 2.0
Active Read - Burst
5
W 1.9 2.1 2.4
Active Read - MAX Burst
6
W 3.4 3.6 3.6
Idle
W 0.5 0.5 0.5
Notes:
1. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) Average Power is
measured using Agilent Power Analyzer over a 100 ms sample period with PLI capacitor charge enabled.
2. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) Burst Power is
measured using Agilent Power Analyzer over a 500 µs sample period with PLI capacitor charge disabled.
3. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential writes. RMS (Root Mean Squared) Max Burst power is
measured using Agilent Power Analyzer over a 500 µs sample period with PLI capacitor charge enabled. Pulse is 0.25% of total time.
4. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) average power is
measured using Agilent Power Analyzer over a 100 ms sample period with PLI capacitor charge enabled.
5. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) burst power is
measured using Agilent Power Analyzer over a 500 µs sample period with PLI capacitor charge disabled.
6. The workload equates 128 KB (131,072 bytes) Queue Depth equal to 32 sequential reads. RMS (Root Mean Squared) Max Burst power is
measured using Agilent Power Analyzer over a 500 µs sample period with PLI capacitor charge enabled. Pulse is approximately 0.25% of
total time.
Product Specification Addendum January 2015
8 331061-002US