User manual

8 Intel
®
SRCU41L Raid Controller User Manual
Hardware Installation
Select a PCI slot and align the Intel
®
Raid Controller SRCU41L PCI bus connector to the slot.
Press down gently but firmly to ensure that the card is properly seated in the slot, as shown in
Figure 3. Then screw the bracket into the computer chassis.
6. Set the Target IDs.
Set target identifiers (TIDs) on the SCSI devices. Each device in a channel must have a unique
TID. Provide unique TIDs for non-disk devices (CD-ROM or tapes), regardless of the channel
where they are connected. The Intel
®
Raid Controller SRCU41L automatically occupies TID
7, which is the highest priority. The arbitration priority for a SCSI device depends on its TID.
Figure 3. Inserting the Intel
®
SRCU41L Raid Controller in a PCI Slot
Bracket Screw
32-bit Slots (3.3 V)
64-bit Slots (5 V)
Press Here
Press Here
Edge of
Motherboard
Table 2. Target IDs
Priority Highest Lowest
TID 7 6 5 . . . 2 1 0 15 14 . . . 9 8