Datasheet

Intel® Server System SR2500AL Environmental and Regulatory Specifications
Revision – 1.00
Intel order number D31980-004
81
10. Environmental and Regulatory Specifications
10.1 System Level Environmental Limits
The table below defines the system level operating and non-operating environmental limits
Table 55. System Environmental Limits Summary
Parameter Limits
Operating Temperature
+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
Non-Operating
Temperature
-40°C to +70°C
Non-Operating Humidity
90%, non-condensing @ 28°C
Acoustic noise Sound Pressure: 55 dBA (Rack mount) in an idle state at typical office ambient
temperature. (23 +/- degrees C) Sound Power: 7.0 BA in an idle state at typical
office ambient temperature. (23 +/- 2 degrees C)
Shock, operating Half sine, 2 g peak, 11 mSec
Shock, unpackaged Trapezoidal, 25 g, velocity change 136 inches/sec
Shock, packaged
Non-palletized free fall in height 24 inches (40 lbs to < 80 lbs)
Vibration, unpackaged 5 Hz to 500 Hz, 2.20 g RMS random
Shock, operating Half sine, 2 g peak, 11 mSec
ESD +/-15kV except I/O port +/-8KV per Intel Environmental test specification
System Cooling
Requirement in BTU/Hr
1826 BTU/hour
10.2 Product Regulatory Compliance
10.2.1 Product Safety Compliance
The Intel
®
Server Chassis SR2500 complies with the following safety requirements:
UL60950 – CSA 60950(USA / Canada)
EN60950 (Europe)
IEC60950 (International)
CB Certificate & Report, IEC60950 (report to include all country national deviations)
GS License (Germany)
Belarus License (Belarus)
Ukraine License (Ukraine)
CE - Low Voltage Directive 73/23/EEE (Europe)
IRAM Certification (Argentina)
GB4943- CNCA Certification (China)