Datasheet
Intel® Server System SR1640TH TPS Front Panel Control and Indicators
Revision 1.0
Intel order number: E94847-001
78
Table 71. Front LED Indicator Functions
6.2.1 Power / Sleep LED
Table 72. SSI Power LED Operation
Note: Blink rate is approximately 1Hz at 50% duty cycle.
6.2.2 System Status LED
Table 73. System Status LED Operation
Color State Criticality Description
Off N/A Not ready AC power off or BMC initialization completes if no degraded, non-
critical, critical, or non-recoverable conditions exist after AC plug in
Amber Solid On Not ready Pre DC Power On – 15-20 second BMC Initialization when AC is
applied to the server. The system will not POST until BMC
initialization completes.
Green Solid on Ok System ready
Green Blink Degraded BIOS detected
1. Unable to use all of the installed memory (more than one DIMM
installed).
1
2. In a mirrored configuration, when memory mirroring takes place
and system loses memory redundancy. This is not covered by
(2).
1
State Power Mode LED Description
Power Off Non-ACPI Off System power is off and the BIOS has not initialized the chipset.
Power On Non-ACPI Solid On System power is on but the BIOS has not yet initialized the
chipset.
S5 ACPI Off Mechanical is off and the operating system has not saved any
context to the hard disk.
S1 Sleep ACPI Blink DC power is still on. The operating system has saved context and
gone into a level of low-power state.
S0 ACPI Solid On System and the operating system are up and running.