Datasheet

Functional Architecture Intel® Server System SR1640TH TPS
Revision 1.0
Intel order number: E94847-001
34
Setup Item Comments
DIMM_ XY Displays the state of each DIMM socket present on the board.
Each DIMM socket field reflects one of the following possible
states:
Installed: There is a DDR3 DIMM installed in this slot.
Not Installed: There is no DDR3 DIMM installed in this slot.
Disabled: The DDR3 DIMM installed in this slot was disabled by
the BIOS to optimize memory configuration.
Failed: The DDR3 DIMM installed in this slot is faulty /
malfunctioning.
Spare Unit: The DDR3 DIMM is functioning as a spare unit for
memory RAS purposes.
Note: X denotes the Channel Identifier and Y denote the DIMM
Identifier within the Channel.
2.6.5.2.3 Mass Storage Controller Screen
The Mass Storage screen allows the
user to configure the SATA/SAS controller when it is
present on the baseboard, midplane, or backplane of an Intel system.
To access this screen from the Main menu, select Advanced > Mass Storage.
Advanced
Mass Storage Controller Configuration
Onboard SATA Controller Enabled / Disabled
Configure SATA Mode ENHANCED / COMPATIBILITY / AHCI / Matrix RAID
SATA Port 0 Not Installed/<Drive Info.>
SATA Port 1 Not Installed/<Drive Info.>
SATA Port 4 Not Installed/<Drive Info.>
SATA Port 5 Not Installed/<Drive Info.>
Figure 13. Setup Utility – Mass Storage Controller Configuration Screen Display
Table 17. Setup Utility – Mass Storage Controller Configuration Screen Fields
Setup Item Options Help Text Comments
Onboard SATA
Controller
Enabled
Disabled
Onboard Serial ATA (SATA)
controller.
SATA Mode
ENHANCED
Compatibility
AHCI
Matrix RAID
[ENHANCED] - Supports up to 6
SATA ports with IDE Native
Mode.
[COMPATIBILITY] - Supports up
to 4 SATA ports[0/1/2/3] with IDE
Legacy mode and 2 SATA
ports[4/5] with IDE Native Mode.
[AHCI] - Supports all SATA ports
using the Advanced Host
Controller Interface.
Intel
®
Matrix RAID Technology
with Software RAID levels 0/1/10
and 5.
Disappears when the Onboard
SATA Controller is disabled.