Specifications
Intel
®
Server System SR1630GPRX/SR1630HGPRX Service Guide 27
Figure 12. CMOS Recovery Jumper
4. Wait five seconds.
5. Move the jumper back to default position, covering pins 1 and 2.
6. Close the server chassis.
7. Reconnect the AC power and power up the system. The CMOS is cleared and can
be reset by going into the BIOS setup.
Updating the Integrated BMC
Figure 13. BMC Force Update Jumper
When performing the standard Integrated BMC firmware update procedure, the update
utility places the Integrated BMC into an update mode, allowing the firmware to load
safely onto the flash device. In the unlikely event the Integrated BMC firmware update
process fails (due to the Integrated BMC not being in the proper update state), the server
3
2
Default
CLEAR
CMOS
J1F5
CMOS
Clear
AF003182
3
2
Default
Enabled
J1E1
BMC
Force
Update
AF003394