Color State Criticality Description
Amber Blink Non-critical
Non-fatal alarm – system is likely to fail:
CATERR asserted.
Critical temperature threshold asserted.
Critical voltage threshold asserted.
Critical fan threshold asserted.
VRD hot asserted.
SMI Timeout asserted.
Amber Solid on
Critical, non-
recoverable
Fatal alarm – system has failed or shutdown:
CPU Missing.
Thermtrip asserted.
Non-recoverable temperature threshold asserted.
Non-recoverable voltage threshold asserted.
Power fault / Power Control Failure.
Fan redundancy lost, insufficient system cooling. This does not
apply to non-redundant systems.
Power supply redundancy lost, insufficient system power. This does
not apply to non-redundant systems.
This state will also happen when AC power is first applied to the
system. This indicates that the BMC is booting.
6.1.3 Drive Activity LED
The drive activity LED on the front panel indicates drive activity from the onboard hard disk