Datasheet
Intel® Server System SR1550AL Environmental and Regulatory Specifications
Revision – 1.3
Intel order number D31982-006
81
12.5 Serviceability and Availability
The system is designed to be serviced by qualified technical personnel only.
The desired Mean Time To Repair (MTTR) of the system is 30 minutes including diagnosis of
the system problem. To meet this goal, the system enclosure and hardware have been
designed to minimize the MTTR.
Following are the maximum times that a trained field service technician should take to perform
the listed system maintenance procedures, after diagnosis of the system and having identified
the failed component.
Activity Time
Estimate
Remove cover 1 min
Remove and replace hard disk drive 5 min
Remove and replace power supply module 1 min
Remove and replace system fan (non-hot swappable) 7 min
Remove and replace system fan (hot swappable) 1 min
Remove and replace backplane board 12 min
Remove and replace midplane board 10 min
Remove and replace control panel module 2 min
Remove and replace server board 15 min
12.6 Restriction of Hazardous Substances (RoHS) Compliance
Intel has a system in place to restrict the use of banned substances in accordance with the
European Directive 2002/95/EC. Compliance is based on declaration that materials banned in
the RoHS Directive are either (1) below all applicable substance threshold limits or (2) an
approved/pending RoHS exemption applies.
Note: RoHS implementing details are not fully defined and may change.
Threshold limits and banned substances are noted below.
• Quantity limit of 0.1% by mass (1000 PPM) for:
o Lead
o Mercury
o Hexavalent Chromium
o Polybrominated Biphenyls Diphenyl Ethers (PBDE)
• Quantity limit of 0.01% by mass (100 PPM) for:
o Cadmium
12.7 Regulated Specified Components
To maintain the UL listing and compliance to other regulatory certifications and/or declarations,
the following regulated components must be used and conditions adhered to. Interchanging or
use of other component will void the UL listing and other product certifications and approvals.
Updated product information for configurations can be found on the Intel Server Builder Web
site at the following URL: http://channel.intel.com/go/serverbuilder
If you do not have access to Intel’s Web address, please contact your local Intel representative.
Server Chassis (base chassis is provided with power supply and fans)⎯UL listed.