Specifications

Intel® Server Board S3420GPRX TPS BIOS User Interface
Revision 1.1
Intel order number E92065-001
65
Setup Item Options Help Text Comments
BMC LAN
Configuration
View/Configure BMC LAN channel and user settings Takes the user to the BMC
configuration screen.
Information only.
Note: This item does not
appear on some models.
See Chapter 3 for product-
specific information.
5.3.2.4.1 Console Redirection Screen
The Console Redirectio
n screen allows the user to enable or disable console redirection and to
configure the connection options for this feature.
To access this screen from the Main screen, select Server Management > Console
Redirection.
Server Management
Console Redirection
Console Redirection Disabled / Serial Port A / Serial Port B
Flow Control
None / RTS/CTS
Baud Rate
9.6k / 19.2k / 38.4k / 57.6k / 115.2k
Terminal Type
PC-ANSI / VT100 / VT100+ / VT-UTF8
Legacy OS Redirection
Disabled / Enabled
Figure 26. Setup Utility – Console Redirection Screen Display
Table 29. Setup Utility – Console Redirection Configuration Fields
Setup Item Options Help Text
Console Redirection Disabled
Serial Port A
Serial Port B
Console redirection allows a serial port to be used for server
management tasks.
[Disabled] - No console redirection.
[Serial Port A] - Configure serial port A for console redirection.
[Serial Port B] - Configure serial port B for console redirection.
Enabling this option disables the display of the Quiet Boot logo
screen during POST.
Flow Control None
RTS/CTS
Flow control is the handshake protocol.
Setting must match the remote terminal application.
[None] - Configure for no flow control.
[RTS/CTS] - Configure for hardware flow control.
Baud Rate 9600
19.2K
38.4K
Serial port transmission speed. Setting must match the remote
terminal application.