Technical Product Specification

Power Sub-system Intel® Server Chassis SC5650 TPS
Revision 1.2
Intel order number E39531-004
20
Table 13. AC Line Surge Transient Performance
Duration Surge Operating AC Voltage Line Frequency Performance Criteria
Continuous 10% Nominal AC Voltages 50/60Hz No loss of function or performance
0 to ½ AC
cycle
30% Mid-point of nominal AC
Voltages
50/60Hz
No loss of function or performance
2.1.4.8 AC Line Fast Transient (EFT) Specification
The power supply meets the EN 61000-4-5 directive and any additional requirements in
IEC1000-4-5:1995 and the Level 3 requirements for surge-withstand capability with the following
conditions and exceptions:
These input transients do not cause any out-of-regulation conditions, such as overshoot
and undershoot, nor do they cause any nuisance trips of any of the power supply
protection circuits.
The surge-withstand test does not produce damage to the power supply.
The power supply meets surge-withstand test conditions under maximum and minimum
DC-output load conditions.
2.1.4.9 AC Line Leakage Current
The maximum leakage current to ground for each power supply is 3.5 mA when tested at 240
VAC.
2.1.5 DC Output Specifications
2.1.5.1 Grounding
The ground of the pins of the power supply output connector provides the power return path.
The output connector ground pins are connected to the safety ground (power supply enclosure).
2.1.5.2 Standby Output
The 5 VSB output is present when an AC input greater than the power supply turn-on voltage is
applied.
2.1.5.3 Fanless Operation
Fanless operation is the power supply’s ability to work indefinitely in standby mode with power
on, power supply off, and the 5 VSB at full load (=2A) under environmental conditions
(temperature, humidity, and altitude). In this mode, the components’ maximum temperature
should follow the same guidelines.