Service Guide

Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 61
3 Hot Swap Drive Cage Upgrade Install
Instructions (optional)
The fixed hard drive cage that ships with your Intel
®
Server Chassis SC5650 is
upgradeable to a hot swap drive cage with a SAS/SATA backplane. See your Intel
Representative for ordering information.
You can install up to six hot swap hard drives in the optional hot swap drive cage. Power
requirements for each individual hard drive may limit the maximum number of drives that
can be integrated into the server chassis.
Note: The Intel
®
Server Chassis SC5650 does not support all hard drives. See “Additional
Information and Software” for a web link to a list of supported hard drives.
Before You Begin
Before working with your server product, review the important safety information listed
in Appendix A, “Safety Information”.
Kits Required
A hot swap conversion kit or a hot-swap drive cooling and mounting kit (part number:
APP3HSDBKIT or APPTHSDBKIT).
OR
A SAS/SATA backplane with expander (part number AXX6DRV3GEXP).
OR
A hot swap drive cage kit with a SAS/SATA backplane without expander (part
number AXX6DRV3GR)
Tools and Supplies Needed
Phillips* (cross head) screwdriver (#1 bit and #2 bit)
Needle-nosed pliers
Anti-static wrist strap and conductive foam pad (recommended)
System References
All references to the left, right, front, top, and bottom assume the reader is facing the front
of the chassis as it would be positioned for pedestal operation.