Service Guide

Hot Swap Drive Cage Upgrade Install Instructions (optional)
Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 73
b. If you are installing a SAS/SATA hot swap backplane without expander:
Warning: SATA controllers cannot be used with an expander backplane.
i. Connect the two power cables (see letter “A” in the following figure) to the
power cable connectors on the SAS/SATA backplane.
ii. Connect a SAS/SATA data cable (see letter “B”) to each appropriate SAS/
SATA connector on the SAS/SATA backplane.
iii. Connect the IPMB cable (see letter “C”).
iv. Connect the SES cable (see letter “D”).
v. Connect the fan power to the server board.
vi. Connect the IPMB cable (see letter “E”). For other Intel
®
server boards, refer to
the Quick Start Users Guide that came with the server board.
Figure 88. Making Six-drive SAS/SATA Hot-Swap Drive Cage Backplane without
Expander Connections (DP/WS/BRP configuration shown - fan bracket not shown in the
illustration for clarity)
AF00449
6-Drive Non-expander
HS Bac
kplane
A
B
HDD 4
HDD 5
HDD 2
HDD 3
HDD 0
HDD 1
E
C
D