Service Guide
Hardware Installations and Upgrades
24 Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide
Installing and Removing a Fixed Hard Drive
You can install up to six fixed hard drives in the fixed hard drive cage that ships with the
Intel
®
Server Chassis SC5650. Power requirements for each individual hard drive may
limit the maximum number of drives that can be integrated into the server chassis.
Note: The Intel
®
Server Chassis SC5650 does not support all hard drives. See “Additional
Information and Software” for a web link to a list of supported hard drives.
Installing a Fixed Hard Drive
Caution: Fixed drives are NOT hot-swappable. Before removing or replacing the drive, you must
first take the server out of service, turn off all peripheral devices connected to the system,
turn off the system by pressing the power button, and unplug the AC power cord from the
system or wall outlet.
Warning: You MUST populate drive bay slots 1, 3, and 5 first. Failure to do so could result in
thermal issues within the chassis.
Note: SAS/SATA drives illustrated.
Figure 21. Drive Bay Slot Order
1. Observe the safety and ESD precautions listed in Appendix A, “Safety Information”.
2. Power down the server and unplug all peripheral devices and the AC power cable.
AF000316
1
2
4
3
5
6