Service Guide

Technical Reference
Intel® Server Chassis SC5650-DP/WS/BRP/UP Service Guide 97
DP 400-W Power Supply Output Voltages
The following table lists the total wattage available from the power subsystem for each
voltage. Ensure your loads do not exceed the combined total wattage of 400 W. For
information about calculating the power usage for your configuration, see "Calculating
Power Usage."
System Environmental Specifications
Table 7. DP 400-W Power Supply Output Capability
Voltage
Maximum
Current
+3.3 V 20 A
+5.0 V 20 A
+5 V Standby 2.5 A
+12.0 V1 16 A
+12.0 V2 16 A
-12.0 V 0.5 A
Table 8. System Environmental Specifications
Temperature
Non-operating
Operating
-40 ° to 70 °C.
10 ° to 35 °C; derated 0.5 °C for every 1000 ft (305 m) to a maximum of
10,000 ft.
Humidity
Non-operating 50% to 90% relative humidity (non-condensing) at 35 °C.
Shock
Operating
Packaged
2.0 g, 11 msec, Halfsine
Operational after an 18" free fall.
Acoustic noise DP, BRP configurations - 5.5 BA LWA idle; 6.0 BA LWA typical operation
WS configuration - 4.8 BA LWA idle; 5.5 BA LWA typical operation
Electrostatic
discharge (ESD)
Air Discharge: 0 to 12.0 kV
Contact Discharge: 0 to 8.0kV